Samsung · Split air conditioners · Samsung WindFree AR50F / AR60F / AR70F (wall-mounted split, R32)
C574Gas leak error
Name in the manufacturer's documentation (service manual): Gas leak error
[1]
In plain words (editorial)
Refrigerant (gas) leak. The service manual names the same checks as for a gas shortage: wrongly connected pipes or communication wires at multi-unit sites, a badly tightened service valve, pipe failure, evaporator or condenser leakage, or a refrigerant shortage.
When to call a service technician: Contact an authorised Samsung service technician.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Steps given by the manufacturer (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 20 manufacturer document – copy from a distributor quote verified
C574 Gas leak error
- [2] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
check the installation environment. : at the site where several units were installed at the same time, check whether communication wire and pipes have been wrongly connected
- [3] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
service valve tightening status defect
- [4] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
pipe failure
- [5] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
evap leakage
- [6] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
cond leakage
- [7] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
shortage of refrigerant