Vaillant · Heat pumps · Vaillant aroTHERM plus with uniTOWER plus
F.732Compressor outlet temperature too high
Name in the manufacturer's documentation (service manual): Compressor outlet temperature too high
[1]
In plain words (editorial)
The compressor outlet temperature is too high (the manual gives above 110 °C). The manual names exceeded application limits, an EEV that does not open correctly, or too little refrigerant; it also lists a leak-tightness test and checking that the service valves are open.
When to call a service technician: Contact a competent heating engineer (installer or Vaillant customer service).
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
Steps given by the manufacturer (source text)
- Check the compressor inlet sensor and outlet sensor[6]
- Check the compressor outlet temperature sensor (TT135)[7]
- Check the EEV (does the EEV move to the limit stop? Use the sensor/actuator test)[8]
- Check the refrigerant volume (see Technical data)[9]
- Carry out a leak-tightness test[10]
- Check whether the service valves on the outdoor unit are open.[11]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
F.732 Compressor outlet temperature too high
- [2] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
The compressor outlet temperature is above 110 °C
- [3] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
Application limits exceeded
- [4] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
EEV does not work or does not open correctly
- [5] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
Refrigerant volume too low (frequent defrosting due to extremely low evaporation temperatures)
- [6] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
Check the compressor inlet sensor and outlet sensor
- [7] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
Check the compressor outlet temper- ature sensor (TT135)
- [8] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
Check the EEV (does the EEV move to the limit stop? Use the sensor/actuator test)
- [9] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
Check the refrigerant volume (see Technical data)
- [10] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
Carry out a leak-tightness test
- [11] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 61 official manufacturer document quote verified
Check whether the service valves on the outdoor unit are open