F.817Freq. converter fault: Compressor

Name in the manufacturer's documentation (service manual): Freq. converter fault: Compressor[1]

In plain words (editorial)

The frequency converter reports a compressor fault – the manual names a defect in the compressor (e.g. short circuit), in the frequency converter, or a defective or loose compressor cable.

When to call a service technician: Contact a competent heating engineer (installer or Vaillant customer service).

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified F.817 Freq. converter fault: Compressor
  2. [2] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified Defect in the compressor (e.g. short circuit)
  3. [3] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified Defect in the frequency converter
  4. [4] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified Connection cable to the compressor is defective or loose
  5. [5] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified Measure the winding resistance in the compressor
  6. [6] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified Measure the frequency converter output between the three phases, (it must be > 1 kΩ)
  7. [7] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified Check the wiring harness and plug connections